The language which is easy to be understood and simple, CDCS exam questions are suitable for any learners no matter he or she is a student or the person who have worked for many years with profound experiences. So it is convenient for the learners to master the CDCS Guide Torrent and pass the exam in a short time. The amount of the examinee is large. For the office workers, they are both busy in their job and their family life; for the students, they possibly have to learn or do other things.
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
With the rapid development of computer, network, and semiconductor techniques, the market for people is becoming more and more hotly contested. Passing a CDCS exam to get a certificate will help you to look for a better job and get a higher salary. If you are tired of finding a high quality study material, we suggest that you should try our CDCS Exam Prep. Because our CDCS exam materials not only has better quality than any other same learn products, but also can guarantee that you can pass the CDCS exam with ease.
NEW QUESTION # 37
The data center has been in operation for about 1 year and 2 months. The dust levels in the computer room are relatively high.
What is the most likely root cause?
Answer: A
Explanation:
High dust levels in a computer room are often due to improperly fitted floorboards. When floorboards are not securely installed or do not fit tightly, they allow dust and particles from the subfloor to enter the room. In a data center, this can lead to high levels of dust that affect air quality and equipment performance.
Detailed Explanation:
Raised floors in data centers can accumulate dust and debris, especially if the floorboards are not properly sealed. Loose or improperly fitted floorboards allow contaminants from the subfloor to enter the data center environment, increasing the dust levels over time. Proper installation and maintenance of floor panels are essential to prevent dust infiltration and maintain clean conditions.
EPI Data Center Specialist References:
EPI training emphasizes proper flooring installation and maintenance to control air quality within data centers. Correctly fitted floorboards prevent dust accumulation from the subfloor, which helps protect sensitive equipment and maintains a cleaner environment.
NEW QUESTION # 38
You need to determine the strategy for the cooling audit. All the servers are based on a front-to-rear (F-R) airflow design.
Which location for the temperature/humidity measurement should you recommend for the audit?
Answer: C
Explanation:
For a cooling audit in a data center, it is essential to measure temperature and humidity where air enters the servers to accurately assess cooling performance. In this case, since all servers have a front-to-rear (F-R) airflow design, measuring at the front/intake of the server will provide a precise understanding of the cooling conditions that the equipment is experiencing.
Detailed Explanation:
Servers with a front-to-rear airflow design draw in cool air from the cold aisle at the front, which is then exhausted into the hot aisle at the rear. By measuring temperature and humidity 50 mm/2 inches from the front intake, you gather data on the air conditions right before it enters the servers, providing an accurate representation of the cooling environment as it directly impacts the equipment.
Measuring in the cold aisle at the front intake ensures that the readings reflect the actual conditions of the incoming air that the servers depend on for effective cooling. This approach is consistent with best practices for maintaining thermal conditions in a data center, as it helps confirm that the cooling systems are delivering air within the required temperature and humidity specifications.
EPI Data Center Specialist References:
According to the EPI Data Center Specialist curriculum, the optimal placement for temperature and humidity sensors is at the intake of the equipment in the cold aisle, as it directly correlates to the environmental conditions affecting the servers. This positioning allows for a more effective audit of cooling performance, which is critical for maintaining the reliability and efficiency of the data center's operations.
NEW QUESTION # 39
You are working on the design of a new facility. The electrical riser of the building with high current power is located close to the area where sensitive IT equipment in the computer room will be located.
What should you recommend to reduce the amount of EMF coming from the electrical riser?
Answer: A
Explanation:
To reduce Electromagnetic Fields (EMF) emanating from the electrical riser near sensitive IT equipment, three-phase power cabling in a combined cable (such as XLPE) is effective. Combined cabling helps reduce EMF by keeping the conductors tightly packed, which minimizes magnetic fields generated by current flow. Cables like XLPE (cross-linked polyethylene) also offer better insulation, which helps mitigate EMF interference with nearby IT equipment.
Detailed Explanation:
Using a combined three-phase cable reduces EMF because the magnetic fields generated by each phase tend to cancel each other out when in close proximity. This arrangement helps reduce the overall magnetic field strength. In addition, XLPE and similar materials provide good insulation, making them a preferred choice for reducing EMF emissions around sensitive equipment.
EPI Data Center Specialist References:
EPI data center best practices recommend mitigating EMF interference through combined cabling arrangements, especially near areas where sensitive IT equipment is located. Reducing EMF is crucial to maintaining equipment reliability and ensuring compliance with safety standards.
NEW QUESTION # 40
Do you need to consider blast protection when designing a data center?
Answer: B
Explanation:
Blast protection should be considered if the data center or its location is a potential target or is near high-risk areas. Blast protection measures can protect both personnel and infrastructure from potential explosion impacts, which could be essential in areas with heightened security risks.
Detailed Explanation:
In areas where there may be risks of terrorist attacks or explosions due to nearby high-risk facilities, implementing blast protection measures helps safeguard the data center's infrastructure. These measures can include reinforced walls, blast-resistant windows, and secure entryways designed to withstand explosive forces.
EPI Data Center Specialist References:
While not specifically mandated by ANSI/TIA-942, EPI training advises considering local risk factors, including proximity to potential targets, when evaluating the need for blast protection. This approach is aligned with risk assessment and mitigation practices to ensure facility security.
NEW QUESTION # 41
When designing a data center network, your company wants to minimize the number of network switches to manage.
What type of physical cabling layout would be the best choice?
Answer: A
Explanation:
An End of Row (EoR) design minimizes the number of network switches, as multiple racks can share a single switch at the end of a row, reducing switch counts and simplifying management. This design centralizes network switching to fewer points, which reduces the complexity and number of switches required compared to a Top of Rack (ToR) design, where each rack typically has its own switch.
Detailed Explanation:
In EoR designs, each row has a single network switch that handles the connections for all racks within that row. This reduces the number of individual switches needed and centralizes network management, which is ideal for minimizing equipment and simplifying infrastructure in the data center.
EPI Data Center Specialist References:
EPI promotes the EoR design as a way to reduce switch counts and streamline management in data centers. This configuration allows for easier scaling and maintenance while maintaining efficient network connectivity.
NEW QUESTION # 42
......
with the development of science and technology, we can resort to electronic CDCS exam materials, which is now a commonplace, and the electronic materials with the highest quality which consists of all of the key points required for the exam can really be considered as the royal road to learning. And you are sure to pass the CDCS Exam as well as getting the related certification under the guidance of our CDCS study guide which you can find in this website easily.